FIG 07 · 4-SLOT GENEVAIDX
4-slot Maltese-cross Geneva turret, drive pin & index indicator needleContinuous driver wheel (d = 44 mm) & crescent locking hubA four-slot Geneva mechanism converts continuous rotation into step-by-step indexing. The drive pin (r₁ = d·sin 45° = 31.1 mm) enters a radial slot at tangent alignment (zero impact velocity), rotates the Maltese cross by 90° over 90° of driver turn, and exits tangentially while the central hub locks the wheel stationary for the remaining 270°.

Fig 07 — Geneva Drive Intermittent Indexer: Continuous Rotation to Intermittent Step Indexing

Δβ = 2π/N = 90° | r_pin = d · sin(π/N) | Dwell: 270° / Index: 90°

1. Governing Physics & Equations

For an N-slot external Geneva drive, shockless entry and exit require a right triangle between the center line d, the pin radius r₁ = d sin(π/N), and the slot radius r₂ = d cos(π/N). For N = 4, indexing occupies (N − 2)/N × 180° = 90° of driver rotation, leaving 270° of positive dwell.

2. Anatomy of the Instrument

  • Continuous Driver Wheel & Roller Pin (lit): Carries the eccentric pin at radius r₁ = 31.1 mm.
  • Four-Slot Maltese Cross (lit): Features 4 radial slots at 90° intervals and 4 concave locking scallops.
  • Central Locking Hub: Mates with the Geneva wheel's concave scallops during the 270° dwell phase.

3. What to Watch as You Interact

Scrub across the −45° to +45° window: watch the drive pin slip smoothly into a radial slot, accelerate the turret to peak angular velocity at 0°, decelerate it back to rest at +45°, and leave it locked for three-quarters of a turn.

4. Engineering Applications

Cinema film projectors (advancing 24 frames/sec while holding each frame still before the shutter), CNC tool-changer carousels, automated bottle-capping turrets, and mechanical watch calendar wheels.